SEDRIS FOCUS v4.1.4.2 Readme
SEDRIS SDK 4.1.4
March 19, 2012
Description
The SEDRIS Focus application is a tool used to examine, edit, and correct SEDRIS
Transmittal Format (STF) files (also called SEDRIS transmittals). Focus can
also run other applications against transmittals, and includes several tools
from the SEDRIS SDK such as Depth, Model Viewer, Rules Checker, and Syntax
Checker.
Contents
- Description
- Release Information, Recent Changes and Updates
- Features
- Limitations, Known Issues and Planned Improvements
- System Requirements
- Additional Documentation
- Contact and Support
Release Information, Recent Changes and Updates
The current version is 4.1.4.2, and is compatible with SEDRIS SDK 4.1.x.
Changes in v4.1.4.2
- Compatibility updates for JRE/JDK 7
- Installer updates and improvements
- Documentation updates
Changes in v4.1.4.1
Changes in v4.1.4.0 and Earlier Versions
Many improvements and changes were made for the v4.1.4.0 release of SEDRIS
Focus; please refer to the full release notes for
additional details.
Return to top.
Features
- Open multiple transmittals simultaneously.
- Create multiple views of a transmittal.
- View and edit the objects in a transmittal.
- Find a specific object in a transmittal by its DRM class or ID.
- Navigate from object to object in an object tree hierarchy.
- Create bookmarks on transmittal objects.
- Copy and paste objects within and across transmittals.
- Create objects and relationships in a transmittal.
- Delete objects and relationships from a transmittal.
- Run an application on a transmittal from the main window.
- Locate an object in post-processing of Syntax or Rules Checker via a GUI.
- Configure GUI and transmittal traversal preferences.
Return to top.
Limitations, Known Issues and Planned Improvements
Limitations and Known Issues
The following limitations and known issues are applicable to this release of
SEDRIS Focus:
- No current support for SE_Interval_Type in Data Table Editor.
- No current support for SE_String in Data Table Editor.
- No direct provision for expanding or eliminating data from <Data Tables>s.
- No provision for importing or exporting data to and from <Data Table> or
<Image> objects.
- When editing an object linked through an association, the result will not be
reflected on the preview pane of that object, although the new attribute
values are stored in STF. (Workaround: select another object and then
re-select the original object to force preview pane refresh.)
- When editing an object through an ITR link, the result will not be shown on
the preview pane of the same object opened explicitly.
- There is a limitation on selecting enumeration type values in the
EDCS_Attribute_Value type when the class that it resides in is a
Property_Characteristic or State_Data.
- In the case of the Property_Characteristic, it is only a problem when the
aggregate Table_Property_Description has an EAC of type enumeration and the
user tries to select “Enumeration” for the EDCS_Attribute_Value in the
Property_Characteristic, otherwise the EDCS_Attribute_Value behaves normally.
- In the case of the State_Data, it has a requirement based on the “state_tag”
field of the State_Related_Features or State_Related_Geometry object that the
State_Data is being used as a link object for. The EDCS_Attribute_Value has
the same problem in this case when it comes to selecting the “Enumeration”
type for the State_Data.
- Both need to query another object to get it’s EAC and then query the EDCS to
get the applicable EECs.
Planned Improvements
The SEDRIS team plans to implement the following new features and functionality
in future versions of SEDRIS Focus:
- Data Table Signature Selector only shows a maximum of 4 <Table Property
Description>s. Need to fix it to show all.
- Add a way for the user to add all the required components to a single object
in a single step.
- Add in capability to retrieve the transmittal’s GIUD.
- Add in capability to allow user to run Defrag and also retrieve valuable data
about the fragmentation and unused bytes in a transmittal.
- Upgrade Data Table Editor to handle SE_Intervals.
Return to top.
System Requirements
Hardware
- Recommended minimum CPU speed for Intel based machines is 650 MHz.
- Recommended minimum RAM for all supported platforms is 128 MB.
- Minimum disk space required is 50 MB.
Software
- Windows (XP and newer tested), Linux (Ubuntu 10.04 and newer, CentOS 5.6 and
newer, Debian GNU/Linux 5.0 and newer tested), or Mac OS X (10.4 and newer
tested)
JRE (Java Runtime Environment) version 1.4.2 or later installed and
functional.
Note: The Windows version of Focus includes a compatible version of the
JRE in the installation package. If you’ve already installed a compatible
JRE on your system, you can de-select this option during installation to
save considerable disk space.
Return to top.
Additional Documentation
Return to top.
Contact and Support
Send email to help@sedris.org for questions or
assistance in using this application. As a minimum, please provide the
following in your email:
- Application name and version (SEDRIS Focus 4.1.4.2)
- Hardware architecture
- OS name and version
- JRE version
- A detailed problem description
- Detailed instructions on how to reproduce the problem
Return to top.